FC-9821ke Installation environmental conditions

In the FA environment, FC-9821Ke Series may cause malfunction, so it is necessary to use it with sufficient consideration for the following installation environment conditions.

Simple dust-proof filter set (FC-9821KE-E03) When the nec product installed, an air cooling fan (FC-9821KE-E05) is required.

When the FDD/HDD is not built-in:
Viper temperature*1:0 to 45 ℃*2 (0 to 50 ℃)*3 (0 to 45 ℃)*4
Save temperature*5:-20-65 ℃
Operation humidity(non-condensed):20~90%
Save humidity (non-condensed):20~90%
Floating dust:Not particularly bad
Corrosion gas:Absence
Earthquake resistance (16.7Hz xyz 30 minutes each):1.6G
Shock resistance (3 times in each direction):10G
Power-supply voltage:AC100V/110V + 10%, -15%(AC85-121V)
Power frequency:50/60Hz ± 1Hz
Power noise:1KVP-P 50NS-1us pulse
Insulation resistance value:20m ohm (DC500V)
Insulated pressure:AC1.5kv 1 minute
Leakage current:1 ma or less
Instant power outage:30ms or less

When built-in FDD/HDD:
Viper temperature*1:5-35 ℃*2 (5-45 ℃)*3 (5-40 ℃)*4
Save temperature*5:-20~60℃
Operation humidity(non-condensed):20~80%
Save humidity (non-condensed):20~80%
Floating dust:Not particularly bad
Corrosion gas:Absence
Earthquake resistance (16.7Hz xyz 30 minutes each):0.5G
Shock resistance (3 times in each direction):10g (when built-in FDD) 2G(when HDD built-in)
Power-supply voltage:AC100V/110V + 10%, -15%(AC85-121V)
Power frequency:50/60Hz ± 1Hz
Power noise:1KVP-P 50NS-1us pulse
Insulation resistance value:20m ohm (DC500V)
Insulated pressure:AC1.5kv 1 minute
Leakage current:1 ma or less
Instant power outage:30ms or less